– All mechanical structure, freely adjustable in both forward and backward.<\/p>
– The user can lock the stroke rigidly in any position.<\/p>
– No air or oil leakage issue compared to normal gas spring.<\/p>
– The linear position can be adjusted without bouncing force.<\/p>
– Widely used on wheelchair adjusters or other medical products<\/p>
Specification<\/strong><\/p>Length of outer tube: Min. 124MM<\/p>
Stroke: Customize according to your needs<\/p>
End fitting: Standardized final accessories to choose<\/p>
Switch: Parallel release\/Perpendicular release\/Plastic lever<\/p>
Finish: Electrophoretic deposition (black)\/Chrome plating (silver)<\/p>
Compression load capacity: Customized<\/p>
Tension load capacity: Customized<\/p>
Sliding friction: Less than 3 kg<\/p>
Net weight: About 0.4 kg (It varies with customization.)<\/p>
*The above information in the description is based on the test result of TKS-P03-F01(6)-150-180-R1.<\/p>
Install Demonstration<\/strong><\/p>
<\/p>
\u00a0<\/p>
\u00a0<\/p>
\u00a0<\/p>
\u00a0<\/p>
\u00a0<\/p>
\u00a0<\/p>
\u00a0<\/p>
Comparison of FOGIM\u2019s linear positioning parts<\/span><\/p>\u00a0<\/th> | Gas Spring<\/th> | Spring Stopper Adjuster<\/th> | Gas Spring Stopper<\/th><\/tr><\/thead> |
---|
ADVANTAGE<\/td> | \u25cfVarious length options for the \u00a0\u00a0\u00a0\u00a0cylinder<\/p> \u25cfLight weight operation by \u00a0\u00a0\u00a0\u00a0customized strutting force<\/p><\/td> | \u25cf No oil\/air leakage causing possible defects<\/p> \u25cf No maintenance required<\/p> \u25cf Easily stopped at any position within stroke \u00a0\u00a0\u00a0\u00a0range without any bouncing<\/p> \u25cf High loading capacity<\/p><\/td> | \u25cf Locking device remains functional after \u00a0\u00a0\u00a0\u00a0air is run out<\/p> \u25cf Highly secured at locking position<\/p> \u25cf Poccess advantages of gas spring and \u00a0\u00a0\u00a0\u00a0spring stopper adjuster<\/p> \u25cf High loading capacity<\/p><\/td><\/tr> |
DISADVANTAGE<\/td> | \u25cf Bounce at locking position<\/p> \u25cf Concerns of oil\/air leakage<\/p> \u25cf Air leakage leads to defects on \u00a0\u00a0\u00a0\u00a0locking device<\/p> \u25cf Limited loading capacity<\/p><\/td> | \u25cf No strut force (except P07 series)<\/td> | \u25cf Constraint on the minimum length of \u00a0\u00a0\u00a0\u00a0the cylinder<\/td><\/tr><\/tbody><\/table><\/div><\/div>\n\t\t\t\t\t\t\t\t\tOrder Instruction<\/div>\n\t\t\t\t\t Code of Spring Stopper Adjuster Series: TKS<\/p>
1. The outer tube type: P03<\/p> 2. The length of outer tube: MIN. 124mm<\/p> 3. Choose the end fitting: F01~F06<\/p> 4. MIN\/MAX distance between two hole centers<\/p> 5. Stroke (Customized according to your demand)<\/p> 6. Choose the switch type:<\/p> R1 parallel release \/ R2 perpendicular release \/ R3 plastic lever<\/p> 7. Switch direction: Left \/ Right<\/p> 8. Finish: Electrophoretic deposition (black)\/Chrome plating (silver)<\/p> <\/p>

 <\/p>
<\/p>
\u00a0<\/p> \u00a0<\/p>  <\/p><\/div>\n\t\t\t\t\t\t\t\t\t
FAQ<\/div>\n\t\t\t\t\t Q1. What is mechanical lock (spring stopper adjuster)? Is this same as the gas spring?<\/span><\/strong><\/p>A1. It is a linear actuator which comprises the locking springs, the rod, outer tube, actuator lever and the attached ends. You can use mechanical lock to lock the stroke rigidly in any position. Mechanical lock doesn\u2019t have air and oil leakage issues compared to gas spring. It can be applied to anywhere you want to adjust the linear position without any bouncing force (a gas spring commom problem).<\/div> \u00a0<\/div> Q2. What is gas spring stopper?<\/span><\/strong><\/p>A2. It combines gas spring and mechanical lock. It has not only the strong thrusting force like gas spring but also rigid locking when exact position is necessary. Gas spring stopper makes a rigid mechanical locking connection with thrust force from gas spring.<\/div> \u00a0<\/div> Q3. What is the difference between mechanical lock and gas spring stopper?<\/span><\/strong><\/p>A3. The gas spring stopper is much longer than the mechanical lock since it combines two parts (gas spring & mechanical lock) together. The gas spring stopper can be applied to the function which requires a force to lift an upwards opening or any loads. The mechanical lock can minimize the length much shorter than the gas spring stopper. It can be applied to the function which needs no force or thrust while locking the stroke rigidly in any position.<\/div> \u00a0<\/div> Q4. What is the difference between gas spring stopper and lockable gas spring?<\/span><\/strong><\/p>A4. Both provide thrust forces to lift loads smoothly and effortlessly. However, lockable gas spring will fail if it wears resulting in air leakage. Our Gas Spring Stopper can still have the locking function controlled by the mechanical lock even when small quantities of air may leak as a sign of wear after lengthy periods of use.<\/div> \u00a0<\/div> Q5. Can you offer some standard products as samples?<\/span><\/strong><\/p>A5. All of our products are customized and the design is based on what our customers want to apply to. So we don\u2019t have any standard product because the dimensions differ from every single demand. You can provide the information about the applications and your design to us, then we can offer you the samples for review.<\/div><\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t |